- Reference Manual PosiChek3 with 32-Bit Software Computerized Performance Tester for Air-Supplied Breathing Apparatus Including Enhanced Precision High Pressure Transducer, Microphone Test and HUD Test Honeywell Analytics, Inc. 405 Barclay Blvd Lincolnshire, IL 60069 (800) 711-6776 FAX 800-995-4992 www.honeywellanalytics.com.
- Honeywell EP, IP, PE Switches and Transducers Honeywell RP418, RP818 Electric/ Pneumatic Relay Honeywell P643 Pneumatic/ Electric Switch Honeywell P658 Pneumatic/ Electric Switch. Manual override crank facilitates installation (all AF and new. MFT is available in all spring return actuators, giving the user the flexibility to customize.
Lee-temp charging, Lee-temp receiver refrigerant level, Table 50 – Liebert Precision Cooling System DS User Manual Page 91: Lee-temp suction pressure transducer settings, Caution. Honeywell Process Solutions Mini-Max PTZ Gas Volume Corrector for Standard Meter Applications User Manual October 2010 V 3.03 Honeywell. 2 www.honeywell.com. 3 Mini-Max Users Guide. Precision strain gauge pressure transducer compensated to minimize ambient temperature effects.
Pressure Systems, Inc. Model 9046 User’s Manual
Page 37 Graco baby swing manual.
www.PressureSystems.com
5.5 Read Primary Transducer A/D Counts (Command ’a’)
Purpose
:
Returns the most recently acquired primary transducer (i.e., temperature/ resistance) raw data
for the specified channels. These data are averaged signed A/D counts (in the range -32768 to
+32767). This simple data bypasses using the transducer’s E. U. conversion coefficients
(c0.c3) and the calibration adjustment coefficients (offset and gain). Each (non-binary) datum
returned in the response will be in the specified high-precision data format. (NOTE: the formula
for converting A/D counts to volts is: Volts = A/D Counts * 5/32768) This command is intended
for advanced users only and is not required for normal operation.
for the specified channels. These data are averaged signed A/D counts (in the range -32768 to
+32767). This simple data bypasses using the transducer’s E. U. conversion coefficients
(c0.c3) and the calibration adjustment coefficients (offset and gain). Each (non-binary) datum
returned in the response will be in the specified high-precision data format. (NOTE: the formula
for converting A/D counts to volts is: Volts = A/D Counts * 5/32768) This command is intended
for advanced users only and is not required for normal operation.
Command
'appppf'
’a’ is the operation code
’pppp’ position field (channel selection bit map)
’f’ is the format field
’a’ is the operation code
’pppp’ position field (channel selection bit map)
’f’ is the format field
Response
' dddd. dddd'
’dddd’ are the data fields, each with leading space
(except f = 7 or 8).
’dddd’ are the data fields, each with leading space
(except f = 7 or 8).
Description
Honeywell Differential Pressure Transducer
: The 4-character hex position field (pppp) specifies a 16-bit binary bit-map, with
each bit (set to 1) to specify a particular channel number (16-1, left-to-right).
The 1-character format field (f) specifies the format of each data field (dddd) that will be returned F150 repair manual download.
in the requested response. The first datum returned in the response will be for the highest
channel number requested. Each (non-binary) datum will be preceded by a space character.
Some formats may not be applicable to the specific type of data being requested. Valid formats
are shown in the following table:
in the requested response. The first datum returned in the response will be for the highest
channel number requested. Each (non-binary) datum will be preceded by a space character.
Some formats may not be applicable to the specific type of data being requested. Valid formats
are shown in the following table:
f
![Manual Manual](/uploads/1/3/3/2/133274237/643211392.jpg)
converts each internal response datum value from:
max.char.
0
single binary float to 7-10-digit signed decimal ' [-xxx]x.xxxxxx'
13
Honeywell Transducers
1
single binary float to 8-digit hex integer ' xxxxxxxx'
2
double binary float to 16-digit hex integer ' xxxxxxxxxxxxxxxx'
17
5
single binary float to long integer (EU*1000) then to 8-digit hex
integer
integer
High Precision Pressure Transducer
9
![Honeywell transducers Honeywell transducers](/uploads/1/3/3/2/133274237/350501679.png)